Configuring MikroTik RB912UAG-2HPnD (BaseBox 2) + Ubiquiti Sector

Recently tuned MikroTik RB912UAG-2HPnD (BaseBox 2).
The sticker says that without the antenna connected it can not be turned on :), it will be used with Ubiquiti Sector AM-2G15, I connected this sector to two contacts.

The standard IP device is 192.168.88.1, the login admin is without a password, DHCP is disabled as standard, so you need to manually register IP on the computer, for example 192.168.88.2 with a subnet mask of 255.255.255.0.

First of all we will change the password in “System” – “Users”.

Set up Wi-Fi settings in “Wireless” – “Interfaces”:
Wireless Protocol: 802.11 so that you can connect to any device

In “Wireless” – “Security Profiles”, configure:
SSID (the name of the wireless network)
Mode: dynamic keys
type of encryption WPA2 PSK AES
WPA2 Pre-Shared Key (wireless password)

Now change the device IP address, in IP – Addresses, the network where it will stand. For example, instead of 192.168.88.1 on 172.16.200.11, after that on the computer, we will manually change the IP registered on the IP from this network, for example 172.16.200.12 so that you can continue to configure.
“IP” – “Routes” add a gateway, for example Dst. Address: 0.0.0.0/0, Gateway: 172.16.200.1.

On this basic setup is completed, the device will work as an access point to the bridge, that is, it will not be issued by the IP, but by the device before it or by billing.