SNMP OID List for iLO4

I made a template for Zabbix today to monitor iLO 4 on the HP DL380p G8 server and had to investigate several OIDs.

You can check the OID from Linux with the command:
snmpwalk 192.168.1.5 -c КОМЬЮНИТИ -v 2c OID

Below is a list and description for OID coolers, processors, temperature sensors, logical drives (RAID), hard disks, network controller iLO, RAM.

Fans:
.1.3.6.1.4.1.232.6.2.6.7.1.2.0 (Fan Index)
.1.3.6.1.4.1.232.6.2.6.7.1.3.0 (Fan Locale (1=other, 2=unknown, 3=system, 4=systemBoard, 5=ioBoard, 6=cpu, 7=memory, 8=storage, 9=removable media, 10=power supply, 11=ambent, 12=chassis, 13=bridge card, 14=management board, 15=backplane, 16=network slot, 17=blade slot, 18=virtual)
.1.3.6.1.4.1.232.6.2.6.7.1.4.0 (Fan Present (1=other, 2=absent, 3=present)
.1.3.6.1.4.1.232.6.2.6.7.1.5.0 (Fan Present (1=other, 2=tachOutput, 3=spinDetect)
.1.3.6.1.4.1.232.6.2.6.7.1.6.0 (Fan Speed (1=other, 2=normal, 3=high)
.1.3.6.1.4.1.232.6.2.6.7.1.9.0 (Fan Condition (1=other, 2=ok, 3=degraded, 4=failed)

Temperature:
.1.3.6.1.4.1.232.6.2.6.8.1.2.0 (Temperature Sensor Index)
.1.3.6.1.4.1.232.6.2.6.8.1.3.0 (Temperature Sensor Locale (1=other, 2=unknown, 3=system, 4=systemBoard, 5=ioBoard, 6=cpu, 7=memory, 8=storage, 9=removable media, 10=power supply, 11=ambent, 12=chassis, 13=bridge card)
.1.3.6.1.4.1.232.6.2.6.8.1.7.0 (Threshold Type (1=other, 5=blowout, 9=caution, 15=critical, 16=noreaction)
.1.3.6.1.4.1.232.6.2.6.8.1.4.0 (Temperature Celsius)
.1.3.6.1.4.1.232.6.2.6.8.1.5.0 (TemperatureThreshold)
.1.3.6.1.4.1.232.6.2.6.8.1.6.0 (TemperatureCondition)

CPU:
.1.3.6.1.4.1.232.1.2.2.1.1.1 (CPU Index)
.1.3.6.1.4.1.232.1.2.2.1.1.3 (CPU Name)
.1.3.6.1.4.1.232.1.2.2.1.1.4 (CPU Speed in MHz)
.1.3.6.1.4.1.232.1.2.2.1.1.5 (CPU Step)
.1.3.6.1.4.1.232.1.2.2.1.1.6 (CPU status (1=unknown, 2=ok, 3=degraded, 4=failed, 5=disabled)
.1.3.6.1.4.1.232.1.2.2.1.1.15 (Number of enabled CPU cores)
.1.3.6.1.4.1.232.1.2.2.1.1.25 (Number of available CPU threads)
.1.3.6.1.4.1.232.1.2.2.1.1.26 (CPU power status (1=unknown, 2=Low Powered, 3=Normal Powered, 4=High Powered)

Logical Drives:
.1.3.6.1.4.1.232.3.2.3.1.1.2.0 (Logical Drive Index)
.1.3.6.1.4.1.232.3.2.3.1.1.1.0 (Logical Drive Controller)
.1.3.6.1.4.1.232.3.2.3.1.1.3.0 (Logical Drive Fault Tolerance (1=other, 2=none, 3=RAID 1/RAID 1+0 (Mirroring), 4=RAID 4 (Data Guard), 5=RAID 5 (Distributed Data Guard), 7=RAID 6 (Advanced Data Guarding), 8=RAID 50, 9=RAID 60, 10=RAID 1 ADM (Advanced Data Mirroring), 11=RAID 10 ADM (Advanced Data Mirroring with Striping))
.1.3.6.1.4.1.232.3.2.3.1.1.9.0 (Logical Drive Size in Mb)
.1.3.6.1.4.1.232.3.2.3.1.1.4.0 (Logical Drive Status (1=other, 2=ok, 3=Failed, 4=Unconfigured, 5=Recovering, 6=Ready Rebuild, 7=Rebuilding, 8=Wrong Drive, 9=Bad Connect, 10=Overheating, 11=Shutdown, 12=Expanding, 13=Not Available, 14=Queued For Expansion, 15=Multi-path Access Degraded, 16=Erasing, 17=Predictive Spare Rebuild Ready, 18=Rapid Parity Initialization In Progress, 19=Rapid Parity Initialization Pending, 20=No Access – Encrypted with No Controller Key, 21=Unencrypted to Encrypted Transformation in Progress, 22=New Logical Drive Key Rekey in Progress, 23=No Access – Encrypted with Controller Encryption Not Enabled, 24=Unencrypted To Encrypted Transformation Not Started, 25=New Logical Drive Key Rekey Request Received)
.1.3.6.1.4.1.232.3.2.3.1.1.11.0 (Logical Drive Condition (1=other, 2=ok, 3=degraded, 4=failed)

Drives:
.1.3.6.1.4.1.232.3.2.5.1.1.2.0 (Drive Index)
.1.3.6.1.4.1.232.3.2.5.1.1.5.0 (Drive Bay)
.1.3.6.1.4.1.232.3.2.5.1.1.64.0 (Drive Location)
.1.3.6.1.4.1.232.3.2.5.1.1.3.0 (Drive Vendor)
.1.3.6.1.4.1.232.3.2.5.1.1.51.0 (Drive Serial Number)
.1.3.6.1.4.1.232.3.2.5.1.1.45.0 (Drive Size in Mb)
.1.3.6.1.4.1.232.3.2.5.1.1.65.0 (Drive Link Rate (1=other, 2=1.5Gbps, 3=3.0Gbps, 4=6.0Gbps, 5=12.0Gbps))
.1.3.6.1.4.1.232.3.2.5.1.1.70.0 (Drive Current Temperature)
.1.3.6.1.4.1.232.3.2.5.1.1.71.0 (Drive Temperature Threshold)
.1.3.6.1.4.1.232.3.2.5.1.1.72.0 (Drive Maximum Temperature)
.1.3.6.1.4.1.232.3.2.5.1.1.6.0 (Drive Status (1=Other, 2=Ok, 3=Failed, 4=Predictive Failure, 5=Erasing, 6=Erase Done, 7=Erase Queued, 8=SSD Wear Out, 9=Not Authenticated)
.1.3.6.1.4.1.232.3.2.5.1.1.37.0 (Drive Condition (1=other, 2=ok, 3=degraded, 4=failed)
.1.3.6.1.4.1.232.3.2.5.1.1.9.0 (Drive Reference Time in hours)

iLO NIC:
.1.3.6.1.4.1.232.9.2.5.2.1.1 (iLO location)
.1.3.6.1.4.1.232.9.2.5.1.1.2 (iLO NIC model)
.1.3.6.1.4.1.232.9.2.5.1.1.4 (iLO NIC MAC)
.1.3.6.1.4.1.232.9.2.5.1.1.5 (iLO NIC IPv4)
.1.3.6.1.4.1.232.9.2.5.1.1.9 (iLO NIC speed)
.1.3.6.1.4.1.232.9.2.5.1.1.14 (iLO NIC FQDN)
.1.3.6.1.4.1.232.9.2.5.2.1.2 (Tx bytes)
.1.3.6.1.4.1.232.9.2.5.2.1.3 (Tx packets)
.1.3.6.1.4.1.232.9.2.5.2.1.6 (Tx discard packets)
.1.3.6.1.4.1.232.9.2.5.2.1.7 (Tx error packets)
.1.3.6.1.4.1.232.9.2.5.2.1.9 (Rx bytes)
.1.3.6.1.4.1.232.9.2.5.2.1.10 (Rx packets)
.1.3.6.1.4.1.232.9.2.5.2.1.13 (Rx discard packets)
.1.3.6.1.4.1.232.9.2.5.2.1.14 (Rx error packets)
.1.3.6.1.4.1.232.9.2.5.2.1.15 (Rx unknown packets)

Memory:
.1.3.6.1.4.1.232.6.2.14.13.1.1 (Memory Index)
.1.3.6.1.4.1.232.6.2.14.13.1.13 (Location)
.1.3.6.1.4.1.232.6.2.14.13.1.9 (Manufacturer)
.1.3.6.1.4.1.232.6.2.14.13.1.10 (Part Number)
.1.3.6.1.4.1.232.6.2.14.13.1.6 (Size in Kbytes)
.1.3.6.1.4.1.232.6.2.14.13.1.8 (Memory Technology)
.1.3.6.1.4.1.232.6.2.14.13.1.7 (Memory Type)
.1.3.6.1.4.1.232.6.2.14.13.1.19 (Memory status (1=other, 2=notPresent, 3=present, 4=good, 5=add, 6=upgrade, 7=missing, 8=doesNotMatch, 9=notSupported, 10=badConfig, 11=degraded, 12=spare, 13=partial)
.1.3.6.1.4.1.232.6.2.14.13.1.20 (Memory condition (1=other, 2=ok, 3=degraded, 4=degradedModuleIndexUnknown)

HP Pavilion dv7 Repair – White Screen

Noticed recently the appearance of a white screen at the time of work on the laptop HP Pavilion dv7.
When switching to an external monitor and back by a combination with the Fn key, the image was displayed normally, but after a while the problem appeared again.

The main reason for this phenomenon is likely to be a damaged or poor contact on the plume going to the display.
In my case, its disconnection/connection did not solve the problem, I had to order it on Aliexpress, it’s not expensive there.
Under the battery is written the full name of the laptop model for which you need to order a cable.

After replacing the loop, the problem was solved.