Приведу пример получения оптического сигнала по SNMP с оптических трансиверов подключенных в Juniper устройства.
Для примера возьму QFX5100 и MX204, сначала командой посмотрим оптический сигнал на трансивере и прочую информацию (в порт et-0/0/0 у меня подключен трансивер 40G, который использует 2 оптических волокна и 4 линии на разной длине волн):
show interfaces diagnostics optics et-0/0/0
show interfaces diagnostics optics et-0/0/0 | match "Laser receiver power"
...
Lane 0
Laser bias current : 39.166 mA
Laser output power : 1.423 mW / 1.53 dBm
Laser receiver power : 0.662 mW / -1.79 dBm
Lane 1
Laser bias current : 33.344 mA
Laser output power : 1.439 mW / 1.58 dBm
Laser receiver power : 0.598 mW / -2.23 dBm
Lane 2
Laser bias current : 33.071 mA
Laser output power : 1.256 mW / 0.99 dBm
Laser receiver power : 0.550 mW / -2.59 dBm
Lane 3
Laser bias current : 35.768 mA
Laser output power : 1.328 mW / 1.23 dBm
Laser receiver power : 0.663 mW / -1.78 dBm
Полный вывод команды:
show interfaces diagnostics optics et-0/0/0
Physical interface: et-0/0/0
Module temperature : 24 degrees C / 74 degrees F
Module voltage : 3.2650 V
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Module temperature high alarm threshold : 78 degrees C / 172 degrees F
Module temperature low alarm threshold : -5 degrees C / 23 degrees F
Module temperature high warning threshold : 75 degrees C / 167 degrees F
Module temperature low warning threshold : 0 degrees C / 32 degrees F
Module voltage high alarm threshold : 3.6300 V
Module voltage low alarm threshold : 2.9700 V
Module voltage high warning threshold : 3.4640 V
Module voltage low warning threshold : 3.0990 V
Laser bias current high alarm threshold : 105.000 mA
Laser bias current low alarm threshold : 8.000 mA
Laser bias current high warning threshold : 105.000 mA
Laser bias current low warning threshold : 10.000 mA
Laser output power high alarm threshold : 3.3884 mW / 5.30 dBm
Laser output power low alarm threshold : 0.0794 mW / -11.00 dBm
Laser output power high warning threshold : 1.9953 mW / 3.00 dBm
Laser output power low warning threshold : 0.1995 mW / -7.00 dBm
Laser rx power high alarm threshold : 2.1380 mW / 3.30 dBm
Laser rx power low alarm threshold : 0.0170 mW / -17.70 dBm
Laser rx power high warning threshold : 1.6982 mW / 2.30 dBm
Laser rx power low warning threshold : 0.0427 mW / -13.70 dBm
Lane 0
Laser bias current : 38.891 mA
Laser output power : 1.406 mW / 1.48 dBm
Laser receiver power : 0.666 mW / -1.76 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser receiver power high alarm : Off
Laser receiver power low alarm : Off
Laser receiver power high warning : Off
Laser receiver power low warning : Off
Tx loss of signal functionality alarm : Off
Rx loss of signal alarm : Off
Tx laser disabled alarm : Off
Lane 1
Laser bias current : 33.344 mA
Laser output power : 1.443 mW / 1.59 dBm
Laser receiver power : 0.599 mW / -2.23 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser receiver power high alarm : Off
Laser receiver power low alarm : Off
Laser receiver power high warning : Off
Laser receiver power low warning : Off
Tx loss of signal functionality alarm : Off
Rx loss of signal alarm : Off
Tx laser disabled alarm : Off
Lane 2
Laser bias current : 33.206 mA
Laser output power : 1.270 mW / 1.04 dBm
Laser receiver power : 0.556 mW / -2.55 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser receiver power high alarm : Off
Laser receiver power low alarm : Off
Laser receiver power high warning : Off
Laser receiver power low warning : Off
Tx loss of signal functionality alarm : Off
Rx loss of signal alarm : Off
Tx laser disabled alarm : Off
Lane 3
Laser bias current : 35.633 mA
Laser output power : 1.335 mW / 1.25 dBm
Laser receiver power : 0.669 mW / -1.74 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser receiver power high alarm : Off
Laser receiver power low alarm : Off
Laser receiver power high warning : Off
Laser receiver power low warning : Off
Tx loss of signal functionality alarm : Off
Rx loss of signal alarm : Off
Tx laser disabled alarm : Off
Заранее посмотрим индексы интерфейсов:
snmpwalk -v2c -c ixnfo.com 10.0.150.2 ifDescr
...
IF-MIB::ifDescr.6 = STRING: lo0
IF-MIB::ifDescr.516 = STRING: irb.0
IF-MIB::ifDescr.517 = STRING: et-0/0/0
Как видим et-0/0/0 имеет индекс 517, теперь получим общую информацию по следующему SNMP OID:
1.3.6.1.4.1.2636.3.60.1
У меня отобразилась информация (результат нужно умножить на 0.01):
RX:
1.3.6.1.4.1.2636.3.60.1.2.1.1.6.517.0 = INTEGER: -178
1.3.6.1.4.1.2636.3.60.1.2.1.1.6.517.1 = INTEGER: -223
1.3.6.1.4.1.2636.3.60.1.2.1.1.6.517.2 = INTEGER: -255
1.3.6.1.4.1.2636.3.60.1.2.1.1.6.517.3 = INTEGER: -179
TX:
1.3.6.1.4.1.2636.3.60.1.2.1.1.8.517.0 = INTEGER: 159
1.3.6.1.4.1.2636.3.60.1.2.1.1.8.517.1 = INTEGER: 160
1.3.6.1.4.1.2636.3.60.1.2.1.1.8.517.2 = INTEGER: 99
1.3.6.1.4.1.2636.3.60.1.2.1.1.8.517.3 = INTEGER: 122
Bias current:
1.3.6.1.4.1.2636.3.60.1.2.1.1.7.517.0 = INTEGER: 39166
1.3.6.1.4.1.2636.3.60.1.2.1.1.7.517.1 = INTEGER: 33344
1.3.6.1.4.1.2636.3.60.1.2.1.1.7.517.2 = INTEGER: 32937
1.3.6.1.4.1.2636.3.60.1.2.1.1.7.517.3 = INTEGER: 35500
Температура трансивера (°C):
1.3.6.1.4.1.2636.3.60.1.1.1.1.8.517 = INTEGER: 23
1.3.6.1.4.1.2636.3.60.1.2.1.1.9.517.0 = INTEGER: 23
1.3.6.1.4.1.2636.3.60.1.2.1.1.9.517.1 = INTEGER: 23
1.3.6.1.4.1.2636.3.60.1.2.1.1.9.517.2 = INTEGER: 23
1.3.6.1.4.1.2636.3.60.1.2.1.1.9.517.3 = INTEGER: 23
Напряжение (3.2650 V):
1.3.6.1.4.1.2636.3.60.1.1.1.1.25.517 = INTEGER: 3265
На примере SNMP OIDs которые я привел, можно написать в Zabbix автообнаружение, чтобы триггеры о низком оптическом сигнале и элементы данных для оптического сигнала и т.д. создавались автоматически при подключении в порты новых трансиверов.