I will give an example of aggregation of two links into one on the HP 5800, in order to increase throughput. 1 Gbit/s + 1Gbit/s = 2Gbit/s. In the test on VLAN 400 without a tag, the Internet comes, and on a VLAN with tags other services.

Add an interface:

interface Bridge-Aggregation1
 port link-type hybrid
 undo port hybrid vlan 1
 port hybrid vlan 963 3659 to 3660 tagged
 port hybrid vlan 400 untagged
 port hybrid pvid vlan 400
 link-aggregation mode dynamic

Settings on the first port:

interface GigabitEthernet1/0/1
 port link-mode bridge
 port link-type hybrid
 undo port hybrid vlan 1
 port hybrid vlan 963 3659 to 3660 tagged
 port hybrid vlan 400 untagged
 port hybrid pvid vlan 400
 loopback-detection enable
 loopback-detection control enable
 loopback-detection per-vlan enable
 flow-interval 5
 storm-constrain broadcast pps 200 150
 storm-constrain control block
 port link-aggregation group 1

Settings on the second port:

interface GigabitEthernet1/0/2
 port link-mode bridge
 port link-type hybrid
 undo port hybrid vlan 1
 port hybrid vlan 963 3659 to 3660 tagged
 port hybrid vlan 400 untagged
 port hybrid pvid vlan 400
 loopback-detection enable
 loopback-detection control enable
 loopback-detection per-vlan enable
 flow-interval 5
 storm-constrain broadcast pps 200 150
 storm-constrain control block
 port link-aggregation group 1

I note that in the port settings there is too much, but for example, settings for protection from loops and control of broadcast traffic can be useful.