I’ll write below a few popular SNMP OIDs for FoxGate switches.
CPU usage:
SNMPv2-SMI::enterprises.6339.100.1.11.10
switchCpuUsage
Temperature:
SNMPv2-SMI::enterprises.6339.100.1.11.9
switchTemperature
CPU idle on average for 5 seconds:
SNMPv2-SMI::enterprises.6339.100.1.11.2
switchCPUFiveSecondIdle
CPU idle on average for 30 seconds:
SNMPv2-SMI::enterprises.6339.100.1.11.3
switchCPUThirtySecondIdle
CPU idle on average for 5 minutes:
SNMPv2-SMI::enterprises.6339.100.1.11.4
CPU idle:
SNMPv2-SMI::enterprises.6339.100.1.11.5
switchCPUIdle
Memory Size:
SNMPv2-SMI::enterprises.6339.100.1.11.6
switchMemorySize
Used memory:
SNMPv2-SMI::enterprises.6339.100.1.11.7
switchMemoryBusy
Flash size:
SNMPv2-SMI::enterprises.6339.100.1.11.8
switchFlashSize
FDB table:
.1.3.6.1.2.1.17.4.3.1
.1.3.6.1.2.1.17.7.1.2
See also my article:
SNMP OID and MIB for interfaces