I noticed one night on the Xiaomi Redmi 10 phone that the screen often lights up, while there were no sounds or vibrations.
Continue reading “The screen lights up on Xiaomi smartphones”Author Archives: Vyacheslav
Configuring ETP48100-B1 with Huawei OLT
In this article I will show how I connected the ETP48100-B1 power supply to Huawei MA5608T.
Huawei ETP48100-B1 is very powerful and heavier than similar models, it is 48V 50A, but from the minuses – batteries cannot be connected to it, that is, it does not have a UPS function.
Zabbix: icmpping “Ping item must have target or host interface specified”
Once I upgraded Zabbix to version 6.4 and noticed that the “Template ICMP Ping” template stopped working on new devices, it continued to work on old ones, but if you add a new device, a warning was displayed:
Continue reading “Zabbix: icmpping “Ping item must have target or host interface specified””Zabbix. Upgrading the database to primary keys
Starting with Zabbix 6.0, primary keys are used for all tables in new installations, but since I upgraded Zabbix server to version 6.4, I had to manually update the tables after the upgrade.
Before updating, first of all, open the menu “Report” – “System Information” and make sure that the keys are not used, this will be indicated by the entry – “Database history tables use primary key – No”, if the keys are used, then this entry simply will not be.
Continue reading “Zabbix. Upgrading the database to primary keys”How to add EPON ONT on MA5608T
In this article, I will show an example of adding EPON ONT on Huawei MA5608T.
I will use ONT from different manufacturers, EPON board H803EPFD for 16 ports.
Restricting access to management on Huawei S2326TP-EI
I will give an example of setting up an ACL to restrict access to Telnet, SSH, SNMP on Huawei S2300 series switches.
Continue reading “Restricting access to management on Huawei S2326TP-EI”Setting up ETP4830 A1 with Huawei OLT
For example, I will take the ETP4830 A1 power supply at 48V 15A (there is a model for 30A) and connect it to the MA5608T so that I can monitor the percentage of battery charge, set the correct parameters for charging batteries (default 53.5V floating and 56.5V accelerated) their capacity (the default is 40Ah or 65Ah), etc.
SNMP MIB/OID for Huawei ETP4830
Let’s say a Huawei ETP4830 power supply unit (UPS) or a similar model is connected to the Huawei OLT MA5600 series, now I will show several SNMP OIDs with which I took data on voltage and battery charge:
Continue reading “SNMP MIB/OID for Huawei ETP4830”SAMSUNG Galaxy M21 Hard Reset
I will give an example of resetting all settings and deleting user data on the SAMSUNG Galaxy M21 phone.
Continue reading “SAMSUNG Galaxy M21 Hard Reset”WordPress. There has been a critical error on your website
Once on one of the sites auto-update of plugins was enabled, and after automatic Jetpack update, the site stopped working and an error was displayed:
Continue reading “WordPress. There has been a critical error on your website”